摄像应用

Only measure facial temperature; high temperature directly triggers a red code. Visible light for face recognition, infrared for temperature measurement.

3601

ThermalWhistle ThermalCam · Dual‑spectral Forehead Temperature Screening

Only measures facial temperature; high temperature is flagged in red. ThermalWhistle overlays the visible‑light camera and the MLX90640 thermal imager onto a single 480×360 display. When a person steps into the frame and remains steady, the device locks a single forehead temperature and displays PASS or FEVER.

Operation Guide

Current Features

  1. Install Modules: The camera is in the left slot, the thermal imager in the right slot. If either is missing, the top will not show PASS but will indicate waiting for module, CAM STALE, or IR STALE.
  2. One Person in Frame: Only a single face is accepted. If two faces appear simultaneously, the top displays ONE PERSON and no temperature is locked.
  3. Stay Still: After a single person and a valid forehead temperature, the top changes to HOLD STILL. When the face position and size remain roughly stable for about 0.6 s, it switches to MEASURING, then takes the median of a short series of readings.
  4. View Locked Result: When measurement ends, a large temperature value and PASS or FEVER are displayed. This number no longer changes with the next person in the frame. FEVER triggers a motor alert.
  5. Release Next Person: Tap the status capsule at the top. After the result is cleared, scanning resumes and the next person can be locked again.
  6. Switch Display: Tap the Mode button at the top right, or press the onboard AI key, to cycle through CAM, AI, Blend, and IR. AI overlays the thermal map only on the facial region, Blend fuses the entire frame, and IR shows only the thermal map.
  7. View Raw Temperature: Tap Body+1.8 at the bottom right to toggle between surface‑compensated and raw infrared temperatures. The selection is stored on the device and persists after reboot.
  8. Tap to Measure: Tap a location in the frame to display a crosshair and a temperature capsule; tapping the capsule clears it. This spot measurement does not replace the locked screening result.

Application Tips

  • Multiple people, no person, temperature outside the skin range, or the camera/thermal map not receiving a new frame for about 0.75 s will not automatically yield PASS.
  • When compensation is enabled, the reading is the skin temperature plus approximately 1.8 °C, with a slight adjustment based on ambient temperature.
  • The thermal map sub‑page runs at roughly 31 fps; the visible‑light stream runs at about 12–15 fps.

Future Pairings

The current version completes screening using the onboard touch, AI key, and left/right slot modules. No joystick is required.

Technical Overview

  • Hardware: ESP-Mosaico (ESP32‑S31), left slot SC101IOT, right slot MLX90640
  • Category: Sensors / Display and HMI
  • License: Apache‑2.0
  • Firmware: Iris, version 1.0.0