Software
Thermal Whistle (visible light + thermal imaging temperature measurement) ThermalCam200186
This page was translated by AI and may differ from the original
Only measure facial temperature; high temperature directly triggers a red code. Visible light for face recognition, infrared for temperature measurement.
Hot Whistle ThermalCam · Dual‑spectral Body‑temperature Screening
Only measures facial temperature; high temperature directly yields a red code. Hot Whistle overlays the visible‑light camera and the MLX90640 thermal imager onto a single 480×360 view. When a person stands in the frame and remains steady, the device locks a single forehead temperature and displays PASS or FEVER.
Thermalcam V1.1.0 Release Notes | 2026-11-16
- IR stability fix: enabled I²C hardware glitch filtering, improving intermittent stream loss, unavailability, and repeated initialization issues when the dual cameras run in parallel, while preserving the original sampling rate.
- New UI: integrated THERMALHUD v3, supporting four view modes—CAM, AI, BLEND, IR—and sensor status display.
- Facial thermal fusion: AI mode overlays IR on the facial recognition region, while BLEND keeps the entire frame fused.
- Tap the temperature display bar to enter settings, adjust the temperature compensation value; after saving, it becomes the default for the next startup. The current default total compensation is +3.0 °C.
- Interaction fix: fixed a bug where photo requests could be lost when switching modes, and added a save‑result notification.
Operation Guide
Currently Available
- Install modules: the camera goes in the left slot, the thermal imager in the right slot. If either is missing, the top will not show PASS; instead it will indicate waiting for module, CAM STALE, or IR STALE.
- One person in frame: only a single face is accepted. If two faces appear simultaneously, the top shows ONE PERSON and no temperature is locked.
- Stay still: after a single person and a valid forehead temperature, the top changes to HOLD STILL. When the face position and size remain roughly stable for about 0.6 s, it switches to MEASURING, then takes the median of a short series of readings.
- View locked result: when measurement ends, a large temperature value and PASS or FEVER are displayed. This number no longer changes with the next person in the frame. FEVER triggers a motor alert.
- Release next person: tap the status capsule at the top. After the result is cleared, scanning resumes and the next person can be locked again.
- Switch view: tap the Mode button at the top‑right, or press the onboard AI key, cycling through CAM, AI, Blend, IR. AI overlays the thermal map only on the facial region, Blend fuses the entire frame, and IR shows only the thermal map.
- View raw temperature: tap Body+1.8 at the bottom‑right to toggle between surface‑compensated and raw infrared values. The selection is stored on the device and persists after reboot.
- Tap‑to‑measure: tap a location in the frame to show a crosshair and temperature capsule; tapping the capsule clears it. This point measurement does not replace the already locked screening result.
Usage Tips
- Multiple people, no person, temperature outside the skin range, or either camera/thermal map missing a new frame for about 0.75 s will not automatically yield PASS.
- When compensation is enabled, the reading is the skin temperature plus roughly 1.8 °C, with a slight adjustment based on ambient temperature.
- Thermal sub‑page runs at about 31 fps; visible light runs at roughly 12–15 fps.
Future Integration
The current version completes screening using the onboard touch panel, AI key, and left/right slot modules. No joystick is required.
Technical Overview
- Hardware: ESP-Mosaico (ESP32‑S31), left slot SC101IOT, right slot MLX90640
- Category: Sensors / Display and HMI
- License: Apache-2.0
- Firmware: Iris, version 1.1.0